Composition:
Modified acrylic dispersion, silicone resins and additives, pigments, fillers, biocides and fungicides, functional additives, water
Color:
White (Base A)
Transparent (Base C)
Gloss level:
Deep matte
Consumption per 1 coat on absorbent surface:
8−10 m²/l*
Consumption per 1 coat on non-absorbent surface:
10−12 m²/l*
Drying time:
1 hour**
Next coat can be applied after:
6 hours**
Resistance to precipitation:
Not earlier than after 12 hours
Wet scrub resistance:
Class 1 GOST 32 300/ DIN EN 13 300
Density:
Base A 1.5−1.55 kg/l; Base C 1.4−1.45 kg/l
Complies with GOST:
R 70 087
Adhesion to concrete GOST 28 574:
1.7 MPa
Water absorption GOST 33 352:
Less than 0.001 kg/(m2*h0.5), class W3
Vapor permeability resistance:
Less than 0.02 m²hPa/mg GOST 25 898
Vapor permeability GOST 33 355:
More than 150 g/(m2·day), class V1, GOST 33 355 Sd 0.01 m
Relative lightfastness GOST 21 903:
Not less than 96 h
Resistance to static effect of water and 3% sodium hydroxide solution GOST 9.403:
Not less than 96 h
*Consumption is affected by the roughness and porosity of the surface being painted, as well as the method and conditions during painting.
**At t (+20±2)ºC and relative air humidity not more than (65±5)%. Drying time may increase at air temperatures below +15°C and relative air humidity above 65% - apply the next coat no earlier than after 24 hours.
High-quality facade paint for use in facade thermal insulation systems based on mineral wool and expanded polystyrene, for painting facades and plinths of buildings and structures, as well as for interior finishing in dry and wet rooms in buildings and structures of types A, B, C.
The silicone-modified composition ensures durability, weather resistance, and the best ratio of high vapor permeability and low water absorption. The paint forms a strong, elastic, self-cleaning hydrophobic coating with a "lotus" effect, resistant to mold and fungi. It can be tinted in pastel and saturated colors.
Tinting and color solutions
The paint is produced in two bases, A and C, and can be tinted by computer (machine) method into RAL, NCS, and other color catalogs. Base A is intended for tinting into light and pastel shades, and can also be used as white paint; it is permissible to add up to 5% of tinting pastes by weight of the paint. Base C is used only in tinted form and is intended for tinting into saturated shades; it is permissible to add up to 10% of tinting pastes by weight of the paint.
When painting in bright colors using Base C, it is recommended to first apply a layer of Base A paint tinted in a similar shade. Manual tinting using water-based tinting pastes is possible.
The organization performing the tinting is responsible for the tinting result.
Color reproduction features
Depending on the application conditions, as well as the texture of the surface being painted, actual color shades may differ slightly from those presented in the color catalog. Before application, it is necessary to perform a test application and check the dried coating for color compliance.
To avoid differences in shade, it is recommended to use a product from the same production batch on one visual plane (the batch number is indicated on each package) or to pre-mix materials from different batches in a 1:1 ratio; the application technology must remain unchanged.
Substrate requirements
The substrate must comply with the requirements of SP 71.13 330.2017:
Concrete, reinforced concrete, cellular concrete — older than 3 months and relative humidity not more than 4%. Cement-sand, cement-lime plasters — 28 days old and relative humidity not more than 4%. BERGAUF ISOFIX, BAU PUTZ ZEMENT, UNTER BAU, GLATTE ZEMENT, FINISH ZEMENT — older than 3 days and relative humidity not more than 6%. Sheet gypsum, cement, wood-containing materials, as well as gypsum plasters — relative humidity not more than 1%.
Working conditions
The surface to be painted must be dry and clean, the substrate temperature for performing work from +5°C, the air temperature during paint application from +5°C to +35°C, relative air humidity below 80%. It is recommended to use paint from the same production batch to exclude color variation of the finish layer.
Material preparation
Stir the paint thoroughly. It is necessary to stir with a wide and flat slat or a construction mixer at low speeds, carefully, avoiding the formation of air bubbles, for 1−3 minutes. It is not recommended to mix the material by shaking the closed can. After transportation and/or active stirring, if air bubbles occur, the paint needs to settle until they disappear.
Application technology
Apply the paint to the prepared dry clean surface with a brush, roller, or spray gun evenly in 2 coats. It is recommended not to take breaks when painting a continuous surface; in places of "overlaps," work using the "wet on wet" method. Work should be finished at architectural boundaries (at the corners of the building, under drainpipes, etc.).
For rough surfaces such as textured plasters, brick, concrete blocks, relief ceilings, it is recommended to use rollers with a pile length of 12−25 mm. For coarse surfaces such as putties, plasters, concrete, fiberglass, painting non-woven fabric — with a pile length of 8−12 mm. For smooth surfaces such as drywall, MDF, chipboard, elements of architectural decor (architraves, moldings, ceiling cornices) — with a pile length of up to 6 mm.
The paint is ready for use; for application by brush or roller, if necessary, dilution with water is possible by no more than 5%.
Precautions
It is forbidden to carry out facade work during precipitation, fog, as well as on wet surfaces after rain and at temperatures below +5 and above +35 °C. During work, avoid exposure to direct sunlight and high humidity conditions.
Upon completion of work, wash hands and tools thoroughly with warm water.
Storage and transportation conditions
Store and transport in tightly closed containers at a temperature of at least +5° and not more than +35°C. Five-fold freezing is allowed for a total duration of no more than 2 weeks at a temperature not lower than -40°C.
The bucket with the product should be protected from excessive heating and storage under direct sunlight should be avoided. Subject to the conditions, the guaranteed shelf life in closed factory packaging is 24 months from the date of manufacture.
During storage, product separation is possible, which is easily eliminated by stirring. Keep partially used product in tightly closed containers and use as quickly as possible.
Safety
The product is fire- and explosion-safe, does not contain flammable components.